BRAND TRANSFERPETTE MANUAL PDF

BRAND offers the ideal pipette for every hand: BRAND’s new Transferpette® S. Transferpette® S models are are the perfect manual pipettes for demand-. Transferpette® electronic. F I R S T C L A S S · B R A N D. Gebrauchsanleitung. Operating Manual. Mode d’emploi. Instrucciones de manejo. 3. -8/ . Testing Instructions (SOP) testing of the piston operated pipette Transferpette®. BRAND additionally provides a calibration service (see chapter 7).

Author: Mazukus Zulugul
Country: Turkey
Language: English (Spanish)
Genre: Politics
Published (Last): 4 February 2004
Pages: 75
PDF File Size: 8.90 Mb
ePub File Size: 20.66 Mb
ISBN: 653-2-51995-705-9
Downloads: 91256
Price: Free* [*Free Regsitration Required]
Uploader: Tulrajas

Safety Instructions Please read the following carefully!

This instrument may sometimes be used with hazardous materials, opera- tions, and equipment. It is beyond the scope of this manual to address all of the potential safety risks associated with its transsferpette in such applications. It is the responsibility of the user of this pipette to consult and establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Limitations of Use Purpose The pipette is an air-displacement system for pipetting aqueous solutions with medium density and low to medium viscosity. Limitations of Use The instrument is intended manal the pipetting of liquids within the following limitations: Consult the manufacturer for use in temperatures outside of this range.

Pipette shaft Tip cone Fig. Optimum analysis results can manuao be obtained with quality tips. For further information, refer to the accuracy table on pages 37 and Pipetting 5 ml and 10 ml instruments should only be used with the PE filter installed see page Pipette tips are disposables items!

Fitting the tip Use the correct tip according to the volume range or the color code.

BRAND Transferpette S Operating Manual

Ensure that the tip is securely seated. Pipetting c Let the pipetting button slide back slowly. In order for the liquid to reach its end position, leave the tip immersed for a few seconds. Discharge sample a Place the pipette tip against the wall of the vessel.

  IVAN VAN SERTIMA BOOKS PDF

Pipetting Ejecting the tip Hold the pipette shaft over a suitable disposal container and press the tip ejection key to the stop. ISO prescribes rinsing the pipette tip once with the sample liquid prior to the actual pipetting process.

Don’t lay the instrument horizontal when the tip is filled. Checking the Volume Depending on use, we recommend inspection of the instrument every 3 to 12 months.

The cycle can, however, be adjusted to individual requirements. Set nominal volume Set volume to the maximum volume indicated on the instrument see page 32 for procedure.

Adjustment — Easy Calibration The instrument is permanently adjusted for aqueous solutions. If the pipette operation is clearly inaccurate, or if the instrument must be adjusted for solutions of different densities and viscosities or specially- shaped pipette tips, adjustments can be made using the Easy Calibration Technique.

Eject the pipette tip. Autoclave the complete pipette without any further disassembling. Inspect the piston and seal for contamination. To do this, affix a tip, and aspirate a sample. Hold the instrument brane, with the sample in the tip for approximately 10 s.

BRAND TRANSFERPETTE S OPERATING MANUAL Pdf Download.

Inspect the pipette tip cone for damage. Inspect the piston and O-Ring-seal for contamination. Parts will differ slightly depending on nominal volume of instrument. Ask your supplier or manufac- turer for the form. The form can also be downloaded from www.

Just send in the instruments to be calibrated, accompanied by an indication of which kind of calibration you wish. Warranty We shall not be liable for the consequences of improper handling, use, servicing, operating or unauthorized repairs of the instrument or the consequences of normal wear and tear especially of wearing parts such as pistons, seals, valves and the breakage of glass as well as the failure to follow the instructions of the operating manual.

  CNB WCL-21S PDF

Also See for Transferpette S Operating manual – pages. Page of 25 Go. Table of Contents Brannd to my manuals Add. Laboratory Equipment Brand dispensette Operating Manual pages.

Safety Instructions Safety Instructions Please read transfwrpette following carefully! Limitations Of Use Limitations of Use Purpose The pipette is an air-displacement system for pipetting aqueous solutions with medium density and low to medium viscosity.

Pipetting Transferpette 5 ml and 10 ml instruments should only be used with the PE filter installed see page Page 8 Pipetting c Let the pipetting button slide back slowly. Page 9 Pipetting Ejecting the tip Hold the pipette shaft over a suitable disposal container and press the tip ejection key to the stop.

Checking The Volume Checking the Volume Depending on use, we recommend inspection of the instrument every 3 to 12 months.

Adjustment – Easy Calibration Adjustment — Easy Calibration The instrument is permanently adjusted for aqueous solutions. Page 17 Inspect the pipette tip cone for damage.

Warranty Information Warranty We shall not be liable for the consequences of improper handling, use, servicing, operating or unauthorized repairs of the instrument or the consequences of normal wear and tear especially of wearing parts such as pistons, seals, valves and the breakage of glass as well as the failure to follow the instructions of the operating manual.

Comments to this Manuals Your Name. Enter text from picture: By pressing ‘print’ button you will print only current page. To print the manual completely, please, download it. Don’t show me this message again. Got it, continue to print. Don’t have an account?