AS NZS 5000.2 PDF

AS/NZS Specifies the construction, dimension and test requirements for single-core and multi-core polymeric insulated and non-metallic sheathed. AS/NZS (R). Electric cables – Polymeric insulated – For working voltages up to and including / V. standard by. AS/NZS Category: Cord and Cables. Description: Electric cables – Polymeric insulated – For working voltages up to and including / V.

Author: Nikree Fenriran
Country: Bolivia
Language: English (Spanish)
Genre: Travel
Published (Last): 19 November 2007
Pages: 464
PDF File Size: 20.28 Mb
ePub File Size: 16.83 Mb
ISBN: 977-9-90071-288-9
Downloads: 84324
Price: Free* [*Free Regsitration Required]
Uploader: Vudojas

The following briefly describes each of the above tests, their purpose and how they relate to the mechanical performance of the cable in terms of installation and long term operation of the cable.

AS/NZS 5000.2

It will be fairly obvious that the thickness of the insulation and nas material must be aligned with the typical use of the product. Some of the common cable insulating materials are listed below:. Join the fight against non-compliant products! These are the two measurements that compliance is confirmed and is required by nearly all cable standards today.

Privacy Policy Terms of Service. In the first part of this article I will address the first dot point only. In the 50002. of insulation thickness, this varies with material type and conductor size. Only the electrical resistance is mandatory. The actual area is not critical nor is it a parameter that must be measured. Type tests need not be repeated unless changes are made in the cable materials or design or manufacturing process.

A variety of cable insulating materials exists in the cable manufacturing industry, all having differing properties, but all having the primary attribute of being suitable as an electrical insulating material. Their differences lie in their cost, processability, dielectric performance, mechanical ws and flexibility to name a few.

To confirm that a cable can hold its rated voltage the cable is subjected to the following checks and test:. As previously explained it is common for low voltage cable standards to define an insulation thickness which varies for different conductor sizes, with the largest conductor having the thickest insulation and sheath.

A 35mm2 copper conductor, for example, does not need to have 35mm2 of copper in it. The insulation thickness on large conductor sizes is greatest due to the greater risk of mechanical damage during handling of large aa heavy cables. Introduction In this article I will try to unravel some of the less known aspects of cable compliance with the overall aim to give the user the correct information to make better informed decision when selecting cable products.

  GREGORIAN CHANT WILLI APEL PDF

The standards referred to in details the test method used to conduct each test. They may soften, but will not flow. To 5000.2 continued in Part 2. The measurement method described above has traditionally been carried out by manual methods and is therefore subject to human error. Type of Business Contractor emp. There has been much publicity recently about the recall of non-compliant building cables, but what does compliance actually mean as far as a cable is concerned and how does it actually relate to performance?

Due to the level of detail required to address this topic it will be presented in two parts. Keep up to date with latest from this campaign through our Facebook page! Then there is the material that is in contact with the conductor. The thickness of insulation xs sheath of cables is done by taking six measurements at the location where the material is thinnest using optical magnification equipment of at least 10X to allow a reading of 0.

Voltage tests performed on cables are done at higher than normal operating levels. This is a very important and often misunderstood issue. PE has significantly greater dielectric strength compared to PVC, which is a blend of a number of ingredients of which Poly Vinyl Chloride is one.

The improved electrical properties of XLPE is a result of the chemical makeup of the material, being almost exclusively polyethylene.

See examples in Figure 1 for various types 500.02 extrusions. In terms of cables the wiring rules makes direct reference to Australian and New Zealand Standards as the principle means to ensure that its scope is fulfilled. These performance requirements are largely based on the mechanical properties of the materials used in cables.

Subscribe to receive the lastest news from the electrical industry brought to you by Voltimum. Ability to Carry Rated Current The ability of an electrical cable to carry its design electric current is largely dependent on the electrical resistance of the conductor.

  FREDERICK FORSYTH EL CUARTO PROTOCOLO PDF

Does it Comply?

The insulation thickness for LV cables is not primarily based on electrical requirements, but more on mechanical considerations. And neither is the diameter of a conductor important as far as compliance is concerned.

It only needs to meet the specified resistance value. This document defines the principles upon which electrical installations must be designed and installed in order to protect people, livestock and property from the risk of electrical shock, fire and physical injury hazards. Modern manufacturing techniques have seen the introduction of automated electronic measurement systems to replace manual methods that provide a significant improvement in repeat accuracy.

The manner in which compliance of these materials is confirmed is complex and will be covered in some detail under the discussion later on insulating materials. The following sections refer to a range of tests that are conducted on cables to ensure compliance. What may be not so obvious is how the thickness is actually measured. Cross-Linked materials are more thermally stable compared to Thermoplastic materials and will not flow when subjected to high operating temperatures.

The remaining dot points will be addressed in part 2. This is a common testing principle where the test object is subjected to a higher stress than it would normally be expected to operate at, with the intention to flush out extrusion defects or weaknesses in the insulation materials. When looking at the impact of non-compliant resistance on the current rating of a cable, its impact is relatively small, as its current rating is proportional to the inverse of the square root of resistance.

Take the online training and add your voice to this campaign!. This is a legally mandated document, and therefore the risk of non-compliance is not only unsafe it is also illegal. This first part looks at the electrical and physical dimensional testing requirements for cables, whilst the second part looks at the range of material tests that cable materials must meet to enable compliance to be obtained.